48 research outputs found

    Implementation of the extended Kalman filter for determining the optical and geometrical properties of turbid layered media by time-resolved single distance measurements

    Get PDF
    In this article we propose an implementation of the extended Kalman filter (EKF) for the retrieval of optical and geometrical properties in two-layered turbid media assuming a dynamic setting, where absorption of each layer was changed in different steps. Prior works implemented the EKF in frequency-domain with several pairs of light sources and detectors and for static parameters estimation problems. Here we explore the use of the EKF in single distance, time-domain measurements, together with a corresponding forward model. Results show good agreement between retrieved and nominal values, with rather narrow analytical credibility intervals, indicating that the recovery process has low uncertainty, especially for the absorption coefficients.Fil: Baez, Guido Rodrigo. Universidad Nacional del Centro de la Provincia de Buenos Aires. Centro de Investigaciones en Física e Ingeniería del Centro de la Provincia de Buenos Aires. - Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tandil. Centro de Investigaciones en Física e Ingeniería del Centro de la Provincia de Buenos Aires. - Provincia de Buenos Aires. Gobernación. Comisión de Investigaciones Científicas. Centro de Investigaciones en Física e Ingeniería del Centro de la Provincia de Buenos Aires; ArgentinaFil: García, Héctor Alfredo. Universidad Nacional del Centro de la Provincia de Buenos Aires. Centro de Investigaciones en Física e Ingeniería del Centro de la Provincia de Buenos Aires. - Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tandil. Centro de Investigaciones en Física e Ingeniería del Centro de la Provincia de Buenos Aires. - Provincia de Buenos Aires. Gobernación. Comisión de Investigaciones Científicas. Centro de Investigaciones en Física e Ingeniería del Centro de la Provincia de Buenos Aires; ArgentinaFil: Grosenick, Dirk. Physikalisch-technische Bundesanstalt; AlemaniaFil: Wabnitz, Heidrun. Physikalisch-technische Bundesanstalt; Alemani

    Cross-Correlation of Motor Activity Signals from dc-Magnetoencephalography, Near-Infrared Spectroscopy, and Electromyography

    Get PDF
    Neuronal and vascular responses due to finger movements were synchronously measured using dc-magnetoencephalography (dcMEG) and time-resolved near-infrared spectroscopy (trNIRS). The finger movements were monitored with electromyography (EMG). Cortical responses related to the finger movement sequence were extracted by independent component analysis from both the dcMEG and the trNIRS data. The temporal relations between EMG rate, dcMEG, and trNIRS responses were assessed pairwise using the cross-correlation function (CCF), which does not require epoch averaging. A positive lag on a scale of seconds was found for the maximum of the CCF between dcMEG and trNIRS. A zero lag is observed for the CCF between dcMEG and EMG. Additionally this CCF exhibits oscillations at the frequency of individual finger movements. These findings show that the dcMEG with a bandwidth up to 8 Hz records both slow and faster neuronal responses, whereas the vascular response is confirmed to change on a scale of seconds

    Characterization of homogeneous tissue phantoms for performance tests in diffuse optics

    Get PDF
    Solid homogeneous turbid phantoms can be employed to mimic the attenuation and angular distribution of light emerging from tissue, e.g., to assess the responsivity of the detection system of diffuse optics instrumentation and to support standardized performance tests of functional near-infrared spectroscopy devices. We present three methods to quantify the wavelength-dependent diffuse transmittance, relying on (1) measurement of radiance exiting the phantom by a detector far from the exit aperture, (2) simple recording of radiance by a power meter close to the exit aperture and correction for the finite distance between phantom surface and detector, (3) determination of the reduced scattering and absorption coefficients by time-resolved diffuse transmittance measurements and forward calculation of the time-integrated diffuse transmittance based on the diffusion model. The implications of the different approximations related to these approaches are discussed. The various methods were applied to characterize solid slab phantoms, and the results were compared. Specifically, for an epoxy-resin based phantom having a thickness of 2 cm, a reduced scattering coefficient of about 0.5/mm and an absorption coefficient of about 0.01/mm, the diffuse transmittance values obtained by the three different methods were found to agree within about 10%

    In Vitro Comparisons of Near-Infrared Spectroscopy Oximeters: Impact of Slow Changes in Scattering of Liquid Phantoms

    Full text link
    Several cerebral oximeters based on near-infrared spectroscopy (NIRS) are commercially available that determine tissue oxygen saturation (StO). One problem is an inconsistency of StO readings between different brands of instruments. Liquid blood phantoms mimicking optical properties of the neonatal head enable quantitative device comparisons. However, occasionally, the reduced scattering coefficient (μ') of these phantoms decreases over time. AIM To investigate whether this decrease in μ' affects the validity of comparison of these devices. StO was measured by several NIRS oximeters simultaneously on a phantom, which exhibited a particularly strong decrease in μ'. We found that a decrease in μ' by ≤16% from baseline led to deviations in StO of ≤3%

    Mechanically switchable solid inhomogeneous phantom for performance tests in diffuse imaging and spectroscopy

    Get PDF
    A mechanically switchable solid inhomogeneous phantom simulating localized absorption changes was developed and characterized. The homogeneous host phantom was made of epoxy resin with black toner and titanium dioxide particles added as absorbing and scattering components, respectively. A cylindrical rod, movable along a hole in the block and made of the same material, has a black polyvinyl chloride cylinder embedded in its center. By varying the volume and position of the black inclusion, absorption perturbations can be generated over a large range of magnitudes. The phantom has been characterized by various time-domain diffuse optics instruments in terms of absorption and scattering spectra, transmittance images, and reflectance contrast. Addressing a major application of the phantom for performance characterization for functional near-infrared spectroscopy of the brain, the contrast was measured in reflectance mode while black cylinders of volumes from ≈20 mm3 to ≈270 mm3 were moved in lateral and depth directions, respectively. The new type of solid inhomogeneous phantom is expected to become a useful tool for routine quality check of clinical instruments or implementation of industrial standards provided an experimental characterization of the phantom is performed in advance

    Non-contact time-resolved diffuse reflectance imaging at null source-detector separation

    Get PDF
    We report results of the proof-of-principle tests of a novel non-contact tissue imaging system. The system utilizes a quasi-null source-detector separation approach for time-domain near-infrared spectroscopy, taking advantage of an innovative state-of-the-art fast-gated single photon counting detector. Measurements on phantoms demonstrate the feasibility of the non-contact approach for the detection of optically absorbing perturbations buried up to a few centimeters beneath the surface of a tissue-like turbid medium. The measured depth sensitivity and spatial resolution of the new system are close to the values predicted by Monte Carlo simulations for the inhomogeneous medium and an ideal fast-gated detector, thus proving the feasibility of the non-contact approach for high density diffuse reflectance measurements on tissue. Potential applications of the system are also discussed. © 2011 Optical Society of America

    Characterization of a time-resolved non-contact scanning diffuse optical imaging system exploiting fast-gated single-photon avalanche diode detection

    Get PDF
    We present a system for non-contact time-resolved diffuse reflectance imaging, based on small source-detector distance and high dynamic range measurements utilizing a fast-gated single-photon avalanche diode. The system is suitable for imaging of diffusive media without any contact with the sample and with a spatial resolution of about 1 cm at 1 cm depth. In order to objectively assess its performances, we adopted two standardized protocols developed for time-domain brain imagers. The related tests included the recording of the instrument response function of the setup and the responsivity of its detection system. Moreover, by using liquid turbid phantoms with absorbing inclusions, depth-dependent contrast and contrast-to-noise ratio as well as lateral spatial resolution were measured. To illustrate the potentialities of the novel approach, the characteristics of the non-contact system are discussed and compared to those of a fiber-based brain imager
    corecore